1
0
mirror of https://github.com/golang/go synced 2024-11-14 21:40:21 -07:00
Commit Graph

17 Commits

Author SHA1 Message Date
Hyang-Ah (Hana) Kim
c24cc40075 cmd/trace: fix a runnable goroutine count bug
When starting tracing, EvGoCreate events are added for existing
goroutines that may have been blocking in syscall. EvGoCreate
increments the runnable goroutine count. This change makes the
following EvGoInSyscall event decrement the runnable goroutine count
because we now know that goroutine is in syscall, and not runnable.

Made generateTrace return an error, at any given time, the number
of runnable/running/insyscall goroutines becomes non-negative.

Added a basic test that checks the number of runnable/running
goroutines don't include the goroutines in syscall - the test failed
before this change.

Change-Id: Ib732c382e7bd17158a437576f9d589ab89097ce6
Reviewed-on: https://go-review.googlesource.com/25552
Run-TryBot: Hyang-Ah Hana Kim <hyangah@gmail.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Dmitry Vyukov <dvyukov@google.com>
2016-10-11 12:07:44 +00:00
Austin Clements
94589054d3 cmd/trace: label mark termination spans as such
Currently these are labeled "MARK", which was accurate in the STW
collector, but these really indicate mark termination now, since
marking happens for the full duration of the concurrent GC. Re-label
them as "MARK TERMINATION" to clarify this.

Change-Id: Ie98bd961195acde49598b4fa3f9e7d90d757c0a6
Reviewed-on: https://go-review.googlesource.com/30018
Reviewed-by: Dmitry Vyukov <dvyukov@google.com>
2016-10-07 18:33:23 +00:00
Austin Clements
eed309f5fb cmd/trace: move process-wide GC events to their own row
Currently, the process-wide GC state is attributed to the P that
happened to perform the allocation that exceeded the GC trigger. This
is pretty arbitrary and makes it hard to see when GC is running since
the GC spans are intermingled with a lot of other trace noise.

The current display is particularly confusing because it creates three
sub-rows in the P row that can overlap each other. Usually a P has
just two sub-rows: one showing the current G and another showing that
G's activity. However, because GC is attributed to a proc, it winds up
as a third row that neither subsumes nor is subsumed by any other row.
This in turn screws up the trace's layout and results in overlapping
events.

Fix these problems by creating a new dedicated row like the existing
"Network" and "Timer" rows and displaying process-wide GC events in
this row. Mark termination and sweep events still appear in their
respective P rows because these are meaningfully attributed.

Change-Id: Ie1a1c6cf8c446e4b043f10f3968f91ff1b546d15
Reviewed-on: https://go-review.googlesource.com/30017
Reviewed-by: Dmitry Vyukov <dvyukov@google.com>
2016-10-07 18:33:12 +00:00
Dmitry Vyukov
7ae273923c cmd/trace: split large traces into parts
Trace viewer cannot handle traces larger than 256MB (limit on js string size):
https://github.com/catapult-project/catapult/issues/627
And even that is problematic (chrome hangs and crashes).
Split large traces into 100MB parts. Somewhat clumsy, but I don't see any other
solution (other than rewriting trace viewer). At least it works reliably now.

Fixes #15482

Change-Id: I993b5f43d22072c6f5bd041ab5888ce176f272b2
Reviewed-on: https://go-review.googlesource.com/22731
Reviewed-by: Hyang-Ah Hana Kim <hyangah@gmail.com>
2016-05-12 17:53:59 +00:00
Dmitry Vyukov
2c9d773f74 misc/trace: update trace viewer html
The old trace-viewer is broken since Chrome 49:
https://bugs.chromium.org/p/chromium/issues/detail?id=569417
It was fixed in:
506457cbd7

This change updates trace-viewer to the latest version
(now it is called catapult).

This version has a bug in the lean config that we use, though:
https://github.com/catapult-project/catapult/issues/2247
So use full config for now (it works, but leads to larger html).
When the bug is fixed we need to switch back to lean config (issue #15302).

Change-Id: Ifb8d782ced66e3292d81c5604039fe18eaf267c5
Reviewed-on: https://go-review.googlesource.com/22013
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
2016-04-14 14:48:04 +00:00
Brad Fitzpatrick
519474451a all: make copyright headers consistent with one space after period
This is a subset of https://golang.org/cl/20022 with only the copyright
header lines, so the next CL will be smaller and more reviewable.

Go policy has been single space after periods in comments for some time.

The copyright header template at:

    https://golang.org/doc/contribute.html#copyright

also uses a single space.

Make them all consistent.

Change-Id: Icc26c6b8495c3820da6b171ca96a74701b4a01b0
Reviewed-on: https://go-review.googlesource.com/20111
Run-TryBot: Brad Fitzpatrick <bradfitz@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Reviewed-by: Matthew Dempsky <mdempsky@google.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
2016-03-01 23:34:33 +00:00
Dmitry Vyukov
e8c4a5b893 cmd/trace: fix static file reference
Use runtime.GOROOT instead of os.Getenv("GOROOT") to reference
trace-viewer html file. GOROOT env var is not necessary set,
runtime.GOROOT has a default value for such case.

Change-Id: I906a720f6822915bd9575756e6cbf6d622857c2b
Reviewed-on: https://go-review.googlesource.com/13593
Reviewed-by: Russ Cox <rsc@golang.org>
2015-08-15 17:38:56 +00:00
Dmitry Vyukov
11f50f41ee cmd/trace: log errors to console in AJAX handler
Fixes #11508

Change-Id: I72e83893b76f75685d6edfe65ca6691d97539226
Reviewed-on: https://go-review.googlesource.com/11864
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
2015-07-02 19:10:00 +00:00
Dmitry Vyukov
1cbbd7f545 cmd/trace: fix time scale
Integrate the latest trace-viewer changes.
It now handles nanoseconds without any issues (thanks to @egonelbre!).
So change timestamps from microseconds to nanoseconds.

Change-Id: I010f27effde7e80c9992e6f276f6912354d27df4
Reviewed-on: https://go-review.googlesource.com/11244
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
Reviewed-by: Egon Elbre <egonelbre@gmail.com>
2015-07-01 10:37:10 +00:00
Dmitry Vyukov
8884fa7476 cmd/trace: sort procs
If you have more than 10 procs, then currently they are sorted alphabetically as
0, 10, 11, ..., 19, 2, 20, ...
Assign explicit order to procs so that they are sorted numerically.

Change-Id: I6d978d2cd439aa2fcbcf147842a643f9073eef75
Reviewed-on: https://go-review.googlesource.com/11750
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
Reviewed-by: Russ Cox <rsc@golang.org>
2015-06-30 16:50:57 +00:00
Dmitry Vyukov
202de394f2 cmd/trace: fix panic in goroutine profile
In generateTrace we check that event timestamp is within the interesting range.
Then later in traceContext.time we double check event time.
However, for some events (e.g. emitSlice) we convert time of ev.Link (slice end) rather than ev itself (slice begin).
Slice end can be outside of the interesting time range, and so traceContext.time crashes.
Remove the check in traceContext.time, check in generateTrace loop is sufficient.

Change-Id: If94e93b5653c5816c0a8dcdd920f15df97616835
Reviewed-on: https://go-review.googlesource.com/11100
Reviewed-by: Andrew Gerrand <adg@golang.org>
2015-06-14 21:57:24 +00:00
Dmitry Vyukov
9a8750b276 misc/trace: update trace viewer
Update to tip to fix #11003 (not possible to select events in chromium).
Fixed #11003

Change-Id: Ibba5d39ca809cfd5cb79c9e6d152b00899d49e08
Reviewed-on: https://go-review.googlesource.com/11062
Reviewed-by: Andrew Gerrand <adg@golang.org>
2015-06-14 20:58:23 +00:00
Josh Bleecher Snyder
951f74c4d0 cmd/...: fix vet issues and cull dead code
Change-Id: Ied0eab872950793b34dd2268055b29c702b07e99
Reviewed-on: https://go-review.googlesource.com/9081
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
Run-TryBot: Josh Bleecher Snyder <josharian@gmail.com>
2015-04-18 01:47:28 +00:00
Dmitry Vyukov
7b0c73aa28 cmd/trace: move goroutine analysis code to internal/trace
This allows to test goroutine analysis code in runtime/pprof tests.
Also fix a nil-deref crash in goroutine analysis code that happens on runtime/pprof tests.

Change-Id: Id7884aa29f7fe4a8d7042482a86fe434e030461e
Reviewed-on: https://go-review.googlesource.com/7301
Run-TryBot: Dmitry Vyukov <dvyukov@google.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Keith Randall <khr@golang.org>
Reviewed-by: Andrew Gerrand <adg@golang.org>
2015-03-11 12:53:24 +00:00
Dmitry Vyukov
9d332a8324 cmd/trace: dump thread id on proc start
Augment ProcStart events with OS thread id.
This helps in scheduler locality analysis.

Change-Id: I93fea75d3072cf68de66110d0b59d07101badcb5
Reviewed-on: https://go-review.googlesource.com/7302
Reviewed-by: Keith Randall <khr@golang.org>
2015-03-11 12:52:41 +00:00
Dmitry Vyukov
919fd24884 runtime: remove runtime frames from stacks in traces
Stip uninteresting bottom and top frames from trace stacks.
This makes both binary and json trace files smaller,
and also makes stacks shorter and more readable in the viewer.

Change-Id: Ib9c80ccc280504f0e235f867f53f1d2652c41583
Reviewed-on: https://go-review.googlesource.com/5523
Reviewed-by: Keith Randall <khr@golang.org>
Run-TryBot: Dmitry Vyukov <dvyukov@google.com>
2015-03-10 14:46:15 +00:00
Dmitry Vyukov
edadffa2f3 cmd/trace: add new command
Trace command allows to visualize and analyze traces.
Run as:
$ go tool trace binary trace.file
The commands opens web browser with the main page,
which contains links for trace visualization,
blocking profiler, network IO profiler and per-goroutine
traces.

Also move trace parser from runtime/pprof/trace_parser_test.go
to internal/trace/parser.go, so that it can be shared between
tests and the command.

Change-Id: Ic97ed59ad6e4c7e1dc9eca5e979701a2b4aed7cf
Reviewed-on: https://go-review.googlesource.com/3601
Reviewed-by: Andrew Gerrand <adg@golang.org>
2015-02-20 18:31:25 +00:00