Only install signal handlers for synchronous signals that become
run-time panics. Set the SA_ONSTACK flag for other signal handlers as
needed.
Fixes#13028.
Update #12465.
Update #13034.
Update #13042.
Change-Id: I28375e70641f60630e10f3c86e24b6e4f8a35cc9
Reviewed-on: https://go-review.googlesource.com/17903
Reviewed-by: Russ Cox <rsc@golang.org>
Run-TryBot: Ian Lance Taylor <iant@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Forward signals to signal handlers installed before Go installs its own,
under certain circumstances. In particular, as iant@ suggests, signals are
forwarded iff:
(1) a non-SIG_DFL signal handler existed before Go, and
(2) signal is synchronous (i.e., one of SIGSEGV, SIGBUS, SIGFPE), and
(3a) signal occured on a non-Go thread, or
(3b) signal occurred on a Go thread but in CGo code.
Supported only on Linux, for now.
Change-Id: I403219ee47b26cf65da819fb86cf1ec04d3e25f5
Reviewed-on: https://go-review.googlesource.com/8712
Reviewed-by: Ian Lance Taylor <iant@golang.org>