Before this CL, Go programs in c-archive or c-shared buildmodes
would not handle SIGPIPE. That leads to surprising behaviour where
writes on a closed pipe or socket would raise SIGPIPE and terminate
the program. This CL changes the Go runtime to handle
SIGPIPE regardless of buildmode. In addition, SIGPIPE from non-Go
code is forwarded.
This is a refinement of CL 32796 that fixes the case where a non-default
handler for SIGPIPE is installed by the host C program.
Fixes#17393
Change-Id: Ia41186e52c1ac209d0a594bae9904166ae7df7de
Reviewed-on: https://go-review.googlesource.com/35960
Run-TryBot: Elias Naur <elias.naur@gmail.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
This reverts commit d24b57a6a1.
Reason for revert: Further complications arised (issue 18100). We'll try again in Go 1.9.
Change-Id: I5ca93d2643a4be877dd9c2d8df3359718440f02f
Reviewed-on: https://go-review.googlesource.com/33770
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Minux Ma <minux@golang.org>
Run-TryBot: Minux Ma <minux@golang.org>
Before this CL, Go programs in c-archive or c-shared buildmodes
would not handle SIGPIPE. That leads to surprising behaviour where
writes on a closed pipe or socket would raise SIGPIPE and terminate
the program. This CL changes the Go runtime to handle
SIGPIPE regardless of buildmode. In addition, SIGPIPE from non-Go
code is forwarded.
Fixes#17393
Updates #16760
Change-Id: I155e82020a03a5cdc627a147c27da395662c3fe8
Reviewed-on: https://go-review.googlesource.com/32796
Run-TryBot: Elias Naur <elias.naur@gmail.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Try to avoid a race condition in the test. Passed 500 times on my
laptop.
Fixes#14956.
Change-Id: I5de2e1e3623832f0ab4f180149f7c57ce7cd23c0
Reviewed-on: https://go-review.googlesource.com/21171
Run-TryBot: Ian Lance Taylor <iant@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
The current runtime attempts to forward signals generated by non-Go
code to the original signal handler. If it can't call the original
handler directly, it currently attempts to re-raise the signal after
resetting the handler. In this case, the original context is lost.
This fix prevents that problem by simply returning from the go signal
handler after resetting the original handler. It only does this when
the original handler is the system default handler, which in all cases
is known to not recover. The signal is not reset, so it is retriggered
and the original handler takes over with the proper context.
Fixes#14899
Change-Id: Ib1c19dfa4b50d9732d7a453de3784c8141e1cbb3
Reviewed-on: https://go-review.googlesource.com/21006
Reviewed-by: Ian Lance Taylor <iant@golang.org>