Tell Windows users how to update Mercurial's library.zip to add some missing dependencies.
Fixes#4745.
R=golang-dev, patrick.allen.higgins, minux.ma, adg
CC=golang-dev
https://golang.org/cl/7558043
"go build" and "go install" were mixing stdout and stderr
from the toolchain, then putting it all on stdout. With this
change, it stays mixed, and is sent to stderr. Because
the toolchain does not create output in a clean compile/install,
sending all output to stderr makese more sense.
Also fix test.bash because of "mktemp: too few X's
in template `testgo'" on Linux.
Fixes#4917.
R=golang-dev, rsc, adg
CC=golang-dev
https://golang.org/cl/7393073
I guess it would be too much to ask for gcc on my machine to give
the same errors as gcc on the builder machines.
R=ken2
CC=golang-dev
https://golang.org/cl/7686044
This brings Mach-O generation more in line with ELF generation.
Having separate sections for the symtab and pclntab mean that we
can find them that way, instead of using the deprecated debug segments.
(And the host linker will keep separate sections for us, but probably
not the debug segments.)
R=ken2
CC=golang-dev
https://golang.org/cl/7688043
Previously it was evaluated once, so re-using the timeout option
repeatedly would always generate the same deadine.
Also switch to doing just one pass over the options, making
the private interface actually useful.
R=golang-dev, dsymonds
CC=golang-dev
https://golang.org/cl/7608045
myrtle$ go version
go version devel +d533352b414d Sat Mar 09 05:39:15 2013 +0100 netbsd/386
myrtle$ time go test -ldflags -hostobj ../misc/cgo/test
ok _/var/project/GoLang/misc/cgo/test 10.962s
68.63s real 49.60s user 19.06s system
myrtle$ uname -a
NetBSD myrtle.plan9.local 6.0_BETA2 NetBSD 6.0_BETA2 (GENERIC) i386
R=rsc
CC=golang-dev
https://golang.org/cl/7641047
Update #4929
Regenerated from FreeBSD-9.1 for amd64 and 386, FreeBSD-CURRENT for arm.
R=devon.odell, minux.ma, rsc
CC=golang-dev
https://golang.org/cl/7438053
The call to the C function runtime.findnull() requires
that we provide the argument at 0(SP).
R=rsc, rminnich, ality
CC=golang-dev
https://golang.org/cl/7559047
The sticking point on 386 has been the "PC relative" relocations
used to point the garbage collection metadata at the type info.
These aren't in the code segment, and I don't trust that the linker
isn't doing something special that would be okay in code but
not when interpreting the pointers as data (for example, a PLT
jump table would be terrible).
Solve the problem in two steps:
1. Handle "PC relative" relocations within a section internally,
so that the external linker never sees them.
2. Move the gcdata and gcbss tables into the rodata section,
where the type information lives, so that the relocations can
be handled internally.
(To answer the obvious question, we make the gc->type
references relative so that they need not be relocated
individually when generating a shared object file.)
R=golang-dev, iant
CC=golang-dev
https://golang.org/cl/7629043
For better printing, I recently changed Name to return "<unnamed>" for templates
with empty names, but this causes trouble for the many packages that used "" as
the template name, so restore the old behavior.
It's usually printed as a quoted string anyway, so it should be fine.
R=golang-dev, dsymonds
CC=golang-dev
https://golang.org/cl/7577044
Also rename the relevant examples and make sure the working one compiles.
R=golang-dev, bradfitz, adg, iant, rsc
CC=golang-dev
https://golang.org/cl/7597043
Otherwise the next goroutine run on the m
can get inadvertently locked if it executes a cgo call
that turns on the internal lock.
While we're here, fix the cgo panic unwind to
decrement m->ncgo like the non-panic unwind does.
Fixes#4971.
R=golang-dev, iant, dvyukov
CC=golang-dev
https://golang.org/cl/7627043
Before this CL, running
cd misc/cgo/test
go test -c
readelf --dyn-syms test.test | grep cgoexp
turned up many UNDEF symbols corresponding to symbols actually
in the binary but marked only cgo_export_static. Only symbols
marked cgo_export_dynamic should be listed in this mode.
And if the symbol is going to be listed, it should be listed with its
actual address instead of UNDEF.
The Linux dynamic linker didn't care about the seemingly missing
symbols, but the BSD one did.
This CL eliminates the symbols from the dyn-syms table.
R=golang-dev
TBR=golang-dev
CC=golang-dev
https://golang.org/cl/7624043
- Introduce MaxAlign constant and use in data layout
and ELF section header.
- Allow up to 16-byte alignment for large objects
(will help Keith's hash changes).
- Emit ELF symbol for .rathole (global /dev/null used by 8c).
- Invoke gcc with -m32/-m64 as appropriate.
- Don't invoke gcc if writing the .o file failed.
R=golang-dev, iant
CC=golang-dev
https://golang.org/cl/7563045
Now the default startup is that the program begins at _rt0_386_$GOOS,
which behaves as if calling main(argc, argv). Main jumps to _rt0_386.
This makes the _rt0_386 entry match the expected semantics for
the standard C "main" function, which we can now provide for use when
linking against a standard C library.
386 analogue of https://golang.org/cl/7525043
R=golang-dev, r
CC=golang-dev
https://golang.org/cl/7551045
Implement what Chrome calls socket "late binding". See:
https://insouciant.org/tech/connection-management-in-chromium/
In a nutshell, if our HTTP client needs a TCP connection to a
remote host and there's not an idle one available, rather than
kick off a dial and wait for that specific dial, we instead
kick off a dial and wait for either our own dial to finish, or
any other TCP connection to that same host to become
available.
The implementation looks like a classic "Learning Go
Concurrency" slide.
Chrome's commit and numbers:
http://src.chromium.org/viewvc/chrome?view=rev&revision=36230
R=golang-dev, daniel.morsing, adg
CC=golang-dev
https://golang.org/cl/7587043
Change 231af8ac63aa (CL 7314062) made runtime.enteryscall()
set m->mcache = nil, which means that we can no longer use
syscall.errstr in syscall.Syscall and syscall.Syscall6, since it
requires a new buffer to be allocated for holding the error string.
Instead, we use pre-allocated per-M storage to hold error strings
from syscalls made while in entersyscall mode, and call
runtime.findnull to calculate the lengths.
Fixes#4994.
R=rsc, rminnich, ality, dvyukov, rminnich, r
CC=golang-dev
https://golang.org/cl/7567043
This CL splits multicast listener tests into two; for IPv4 and
for IPv6. It also removes redundant test inputs and makes sure
that assignment of multicast interface to stablize the tests.
Fixes#4059.
R=golang-dev, bradfitz
CC=golang-dev
https://golang.org/cl/7565043