DragonFlyBSD dropped support for i386 in 4.0 and there is no longer a
dragonfly/386 - as such, remove the Go port.
Fixes#8951Fixes#7580Fixes#7421
Change-Id: I69022ab2262132e8f97153f14dc8c37c98527008
Reviewed-on: https://go-review.googlesource.com/7543
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Reviewed-by: Dave Cheney <dave@cheney.net>
Reviewed-by: Minux Ma <minux@golang.org>
Run-TryBot: Joel Sing <jsing@google.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Updates #9974
This change is in preparation for merging the arm64 platform.
Arm64 does not support SYS_DUP2 at all, so define a new constant to be
the minimum dup(2) version supported. This constant defaults to SYS_DUP2
on all existing platforms.
Change-Id: If405878105082c7c880f8541c1491970124c9ce4
Reviewed-on: https://go-review.googlesource.com/7123
Reviewed-by: Minux Ma <minux@golang.org>
Run-TryBot: Minux Ma <minux@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Dave Cheney <dave@cheney.net>
This change fixes a missing case that a routing address contains an
invalid address family label but it holds a valid length of address
structure.
Also makes test robust.
Fixes#10041.
Change-Id: I2480ba273929e859896697382d1a75b01a116b98
Reviewed-on: https://go-review.googlesource.com/6391
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
In CL 6350, Brad fixed the following system calls
to use the program-wide workding directory:
- bind
- chdir
- create
- open
- remove
- stat
- umount
- wstat
However, Russ Cox pointed out that the mount
system call should be fixed as well.
Change-Id: I6139ed11ba449f18c46e95269f4d0e51be7cec48
Reviewed-on: https://go-review.googlesource.com/6385
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
On Plan 9, the pwd is apparently per-thread not per process. That
means different goroutines saw different current directories, even
changing within a goroutine as they were scheduled.
Instead, track the the process-wide pwd protected by a mutex in the
syscall package and set the current goroutine thread's pwd to the
correct once at critical points.
Fixes#9428
Change-Id: I928e90886355be4a95c2be834f5883e2b50fc0cf
Reviewed-on: https://go-review.googlesource.com/6350
Reviewed-by: David du Colombier <0intro@gmail.com>
Run-TryBot: Brad Fitzpatrick <bradfitz@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Updates #9974
This proposal tackles the body of syscalls which have been replaced,
and are now deprecated in linux. This is needed for the arm64 port as
arm64 is the first linux architecture to remove the "legacy" forms of
these syscalls.
The *AT variants were added in kernel 2.6.16, so well before our 2.6.23
cutoff (hey, it'll even work on RHEL5).
Discussion: https://groups.google.com/forum/#!topic/golang-dev/zpeFtN2z5Fc
Change-Id: I473a7c9a295d6f776fcdc75dcce06cbe9e3564ee
Reviewed-on: https://go-review.googlesource.com/5837
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
Updates #9974
The *at family of syscalls requires some constants to be defined in the
syscall package for linux. Add the necessary constants and regenerate
the ztypes_linux_*.go files.
Change-Id: I6df343fef7bcacad30d36c7900dbfb621465a4fe
Reviewed-on: https://go-review.googlesource.com/5836
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
Updates #9974
This proposal moves the definition of Dup2 from the generic syscall_linux.go
to the GOOS specific variants. This is in preparation for the arm64 port.
For all existing platforms Dup2 is not affected. When arm64 is added we'll use
either a forwarding method to Dup3 or
//sysnb Dup2(oldfd int, newfd int) (err error) = SYS_DUP3
Because mksycall.pl does not sort symbols before generating the output file
the diff includes some unavoidable code moves as Dup2 is processed latter in
the run.
Discussion: https://groups.google.com/forum/#!topic/golang-dev/zpeFtN2z5Fc
Change-Id: Icdedf55bb29e749c4230e1ee371bf9d0bd0cfb38
Reviewed-on: https://go-review.googlesource.com/5835
Reviewed-by: Minux Ma <minux@golang.org>
Run-TryBot: Dave Cheney <dave@cheney.net>
Updates #9974
This proposal moves the definition of Pipe an Pipe2 from the generic
syscall_linux.go to the GOOS specific variants. This is in preparation
for the arm64 port.
For platforms where pipe2(2) is not supported in the minimum 2.6.23 kernel,
amd64 and 386, we retain pipe(2). For all other platforms pipe(2) is removed
and Pipe forwards to pipe2(2).
Because mksycall.pl does not sort symbols before generating the output file
the diff includes some unavoidable code moves as Pipe and Pipe2 are processed
latter in the run.
Discussion: https://groups.google.com/forum/#!topic/golang-dev/zpeFtN2z5Fc
Change-Id: Ie26d6761eeb9760dbaff974ee8bc0d57a9ceaee4
Reviewed-on: https://go-review.googlesource.com/5833
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
Run-TryBot: Brad Fitzpatrick <bradfitz@golang.org>
Rebuild the zsyscall_linux_*.go files in preperation for #9974
The only change is the ppc64/ppc64le files which were not rebuilt when
syscall.use was added.
Change-Id: I804c63731e4900c782025de04ea3585d99688958
Reviewed-on: https://go-review.googlesource.com/5831
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
Makes them compatible with the new asm.
Applied mechanically from vet diagnostics.
Manual edits: the names for arguments in time·now(SB) in runtime/sys_*_arm.s.
Change-Id: Ib295390d9509d306afc67714e3f50dc832256625
Reviewed-on: https://go-review.googlesource.com/5576
Run-TryBot: Russ Cox <rsc@golang.org>
Reviewed-by: Rob Pike <r@golang.org>
This changes fixes two issues with regard to handling routing messages
as follows:
- Misparsing on platforms (such as FreeBSD) supporting multiple
architectures in the same kernel (kern.supported_archs="amd64 i386")
- Misparsing with unimplemented messages such as route, interface
address state notifications
To fix those issues, this change implements all the required socket
address parsers, adds a processor architecture identifying function to
FreeBSD and tests.
Fixes#9707.
Fixes#8203.
Change-Id: I7ed7b4a0b6f10f54b29edc681a2f35603f2d8d45
Reviewed-on: https://go-review.googlesource.com/4330
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Fix many incorrect FP references and a few other details.
Some errors remain, especially in vlop, but fixing them requires semantics. For another day.
Change-Id: Ib769fb519b465e79fc08d004a51acc5644e8b259
Reviewed-on: https://go-review.googlesource.com/5288
Reviewed-by: Russ Cox <rsc@golang.org>
Reverts https://golang.org/cl/119530044 (OS X 10.10 Yosemite beta
14A299l workaround), since it was fixed in the final Yosemite release.
I verified that the C program http://swtch.com/~rsc/readdirbug.c
passes on Yosemite.
Adds a new test to the os package too, to verify that reading a
regular file as a directory fails.
Fixes#9789 (ReadDir: no error if dirname is a file)
Change-Id: I75286cef88fbb2ebccf045b479e33c810749dcbc
Reviewed-on: https://go-review.googlesource.com/4164
Reviewed-by: Dave Cheney <dave@cheney.net>
And the silence of the git-codereview.
Change-Id: If3f7fe2de2ab4c1756f3cef8267199049d468b31
Reviewed-on: https://go-review.googlesource.com/3983
Reviewed-by: Minux Ma <minux@golang.org>
Change-Id: Id6f7fa12084204bc3a200f423c7966ce2a0b63a0
Reviewed-on: https://go-review.googlesource.com/2123
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Reviewed-by: David Crawshaw <crawshaw@golang.org>
Generated from a modified go vet.
Change-Id: Ibe82941283da9bd4dbc7fa624a33ffb12424daa2
Reviewed-on: https://go-review.googlesource.com/2817
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Generated from go vet.
Change-Id: I8fee4095e43034b868bfd2b07e21ac13d5beabbb
Reviewed-on: https://go-review.googlesource.com/2816
Reviewed-by: Ian Lance Taylor <iant@golang.org>
This manually reverts 555da73 from #6372 which implies a
minimum FreeBSD version of 8-STABLE.
Updates docs to mention new minimum requirement.
Fixes#9627
Change-Id: I40ae64be3682d79dd55024e32581e3e5e2be8aa7
Reviewed-on: https://go-review.googlesource.com/3020
Reviewed-by: Minux Ma <minux@golang.org>
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
Generated with a modified version of go vet and tested on android.
Change-Id: I1ff20135c5ab9de5a6dbf76ea2991167271ee70d
Reviewed-on: https://go-review.googlesource.com/2815
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Generated from a script using go vet then read by a human.
Change-Id: Ie5f7ab3a1075a9c8defbf5f827a8658e3eb55cab
Reviewed-on: https://go-review.googlesource.com/2746
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Please see golang.org/cl/2588 for reasons behind the name change.
We also need NO_LOCAL_POINTERS for assembly function with non-zero
local frame size.
Change-Id: Iac60aa7e76f4c2ece3726e28878fd539bfebf7a4
Reviewed-on: https://go-review.googlesource.com/2589
Reviewed-by: Ian Lance Taylor <iant@golang.org>
I would like to create new syscalls in src/internal/syscall,
and I prefer not to add new shell scripts for that.
Replacement for CL 136000043.
Change-Id: I840116b5914a2324f516cdb8603c78973d28aeb4
Reviewed-on: https://go-review.googlesource.com/1940
Reviewed-by: Russ Cox <rsc@golang.org>
OpenBSD 5.5 changed its kernel ABI and OpenBSD 5.6 enabled it.
This CL works on both 5.5 and 5.6.
Fixes#9102.
Change-Id: I4a295be9ab8acbc99e550d8cb7e8f8dacf3a03c5
Reviewed-on: https://go-review.googlesource.com/1932
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Handles the case where the parent is pid 1 (common in docker
containers).
Attempted and failed to write a test for this.
Fixes#9263.
Change-Id: I5c6036446c99e66259a4fab1660b6a594f875020
Reviewed-on: https://go-review.googlesource.com/1372
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Reviewed-by: Russ Cox <rsc@golang.org>
Breaks reading from stdin in parent after exec with SysProcAttr{Setpgid: true}.
package main
import (
"fmt"
"os"
"os/exec"
"syscall"
)
func main() {
cmd := exec.Command("true")
cmd.SysProcAttr = &syscall.SysProcAttr{Setpgid: true}
cmd.Run()
fmt.Printf("Hit enter:")
os.Stdin.Read(make([]byte, 100))
fmt.Printf("Bye\n")
}
In go1.3, I type enter at the prompt and the program exits.
With the CL being rolled back, the program wedges at the
prompt.
««« original CL description
syscall: SysProcAttr job control changes
Making the child's process group the foreground process group and
placing the child in a specific process group involves co-ordination
between the parent and child that must be done post-fork but pre-exec.
LGTM=iant
R=golang-codereviews, gobot, iant, mikioh.mikioh
CC=golang-codereviews
https://golang.org/cl/131750044
»»»
LGTM=minux, dneil
R=dneil, minux
CC=golang-codereviews, iant, michael.p.macinnis
https://golang.org/cl/174450043
No easy way to test (would have to actually trigger some routing
events from kernel) but the code is clearly wrong as written.
If the header says there is a submessage, we need to at least
skip over its bytes, not just continue to the next iteration.
Fixes#8203.
LGTM=r
R=r
CC=golang-codereviews, mikioh.mikioh, p
https://golang.org/cl/164140044
Fix include paths that got moved in the great pkg/ rename. Add
missing runtime/arch_* files for power64. Port changes that
happened on default since branching to
runtime/{asm,atomic,sys_linux}_power64x.s (precise stacks,
calling convention change, various new and deleted functions.
Port struct renaming and fix some bugs in
runtime/defs_linux_power64.h.
LGTM=rsc
R=rsc, dave
CC=golang-codereviews
https://golang.org/cl/161450043
This brings dev.power64 up-to-date with the current tip of
default. go_bootstrap is still panicking with a bad defer
when initializing the runtime (even on amd64).
LGTM=rsc
R=rsc
CC=golang-codereviews
https://golang.org/cl/152570049
This also removes pkg/runtime/traceback_lr.c, which was ported
to Go in an earlier commit and then moved to
runtime/traceback.go.
Reviewer: rsc@golang.org
rsc: LGTM
This approach was suggested in
https://golang.org/cl/138250043/#msg15.
Unlike current version of mksyscall_windows.go,
new code could be used in go.sys and other external
repos without help from asm.
LGTM=iant
R=golang-codereviews, iant, r
CC=golang-codereviews
https://golang.org/cl/143160046