Author SHA1 Message Date
David Chase
e5060c7f75 cmd/internal/gc: move check for large-hence-heap-allocated types into escape analysis
Before this change, the check for too-large arrays (and other large
types) occurred after escape analysis.  If the data moved off stack
and onto the heap contained any pointers, it would therefore escape,
but because the too-large check occurred after escape analysis this
would not be recorded and a stack pointer would leak to the heap
(see the modified escape_array.go for an example).

Some of these appear to remain, in calls to typecheck from within walk.

Also corrected a few comments in escape_array.go about "BAD"
analysis that is now done correctly.

Enhanced to move aditional EscNone-but-large-so-heap checks into esc.c.

Change-Id: I770c111baff28a9ed5f8beb601cf09dacc561b83
Reviewed-on: https://go-review.googlesource.com/10268
Reviewed-by: Russ Cox <rsc@golang.org>
2015-05-22 02:13:54 +00:00
David Chase
b19ec6842d cmd/internal/gc: make indirect calls properly escape-y
Indirect function and method calls should leak everything,
but they didn't.

This fix had no particular effect on the cost of running the
compiler on html/template/*.go and added a single new "escape"
to the standard library:

    syscall/syscall_unix.go:85: &b[0] escapes to heap
in
	if errno := m.munmap(uintptr(unsafe.Pointer(&b[0])),
	                     uintptr(len(b))); errno != nil {

Added specific escape testing to escape_calls.go
(and verified that it fails without this patch)

I also did a little code cleanup around the changes in esc.c.

Fixes #10925

Change-Id: I9984b701621ad4c49caed35b01e359295c210033
Reviewed-on: https://go-review.googlesource.com/10295
Reviewed-by: Russ Cox <rsc@golang.org>
2015-05-22 01:36:11 +00:00
Russ Cox
cf932cd897 all: retire architecture letter in file names, public API
This CL removes the remaining visible uses of the "architecture letter" concept.
(They are no longer in tool names nor in source directory names.)

Because the architecture letter concept is now gone, delete GOCHAR
from "go env" output, and change go/build.ArchChar to return an
error always.

The architecture letter is still used in the compiler and linker sources
as a clumsy architecture enumeration, but that use is not visible to
Go users and can be cleaned up separately.

Change-Id: I4d97a38f372003fb610c9c5241bea440d9dbeb8d
Reviewed-on: https://go-review.googlesource.com/10289
Reviewed-by: Rob Pike <r@golang.org>
2015-05-21 17:32:17 +00:00
Russ Cox
17eba6e6b7 cmd/compile, cmd/link: create from 5g, 5l, etc
Trivial merging of 5g, 6g, ... into go tool compile,
and similarlly 5l, 6l, ... into go tool link.
The files compile/main.go and link/main.go are new.
Everything else in those directories is a move followed by
change of imports and package name.

This CL breaks the build. Manual fixups are in the next CL.

See golang-dev thread titled "go tool compile, etc" for background.

Change-Id: Id35ff5a5859ad9037c61275d637b1bd51df6828b
Reviewed-on: https://go-review.googlesource.com/10287
Reviewed-by: Dave Cheney <dave@cheney.net>
Reviewed-by: Rob Pike <r@golang.org>
2015-05-21 17:31:51 +00:00